ROE Visual JT2.6 Half vs Unilumin Upad IV 2.6
On measurable specs the ROE Visual JT2.6 Half leads 6–4. The Unilumin Upad IV 2.6 can still be the right call where its individual wins — check the highlighted rows — match your constraints.
| Add a panel | ||
|---|---|---|
| Physical | ||
| Pixel pitch | 2.60417 mm | 2.60417 mm |
| Cabinet size (W×H×D) | 500 × 500 × 86 mm | 500 × 500 × 70 mm |
| Weight per cabinet | 5.8 kg | 6.3 kg |
| Weight per m² | 23.2 kg/m² | 25.2 kg/m² |
| Image | ||
| Cabinet resolution | 192 × 192 px | 192 × 192 px |
| Pixel density | 147,456 px/m² | 147,456 px/m² |
| Brightness | 1,300 nits | 1,200 nits |
| Refresh rate | 7,680 Hz | 7,680 Hz |
| Contrast | — | 6,000:1 |
| Viewing angle (H/V) | 160° / 140° | 160° / 160° |
| LED type | SMD | SMD |
| Processing depth | 16 bit | 16 bit |
| Power & thermal | ||
| Average power | 70 W | 40 W |
| Max power | 140 W | 120 W |
| Max power per m² | 560 W/m² | 480 W/m² |
| Thermal load per cabinet | 478 BTU/h | 409 BTU/h |
| Operational | ||
| Environment | Indoor | Indoor |
| IP rating (front) | IP40 | IP30 |
| IP rating (rear) | IP40 | IP30 |
| Operating temperature | -20 to 45 °C | -10 to 45 °C |
| Service access | Front & rear | Front & rear |
| LED lifetime | — | 100,000 h |
| Certifications | CE, ETL, FCC, UKCA, RoHS, WEEE | TUV-CE, UL, CB, FCC, IC, RoHS |
Size a wall with either panel