Leyard VHC-1.8 vs Unilumin UDA II 1.8
On measurable specs the Unilumin UDA II 1.8 leads 8–2. The Leyard VHC-1.8 can still be the right call where its individual wins — check the highlighted rows — match your constraints.
| Add a panel | ||
|---|---|---|
| Physical | ||
| Pixel pitch | 1.875 mm | 1.8605 mm |
| Cabinet size (W×H×D) | 600 × 338 × 72 mm | 640 × 480 × 62 mm |
| Weight per cabinet | 6.5 kg | 7.8 kg |
| Weight per m² | 32.1 kg/m² | 25.4 kg/m² |
| Image | ||
| Cabinet resolution | 320 × 180 px | 344 × 258 px |
| Pixel density | 284,444 px/m² | 288,906 px/m² |
| Brightness | 600 nits | 600 nits |
| Refresh rate | 3,840 Hz | 4,200 Hz |
| Contrast | 5,000:1 | 5,000:1 |
| Viewing angle (H/V) | 160° / 150° | 160° / 140° |
| LED type | SMD | SMD |
| Processing depth | 14 bit | 14 bit |
| Power & thermal | ||
| Average power | 42 W | 23 W |
| Max power | 103 W | 77 W |
| Max power per m² | 510 W/m² | 251 W/m² |
| Thermal load per cabinet | 352 BTU/h | 263 BTU/h |
| Operational | ||
| Environment | Indoor | Indoor |
| IP rating (front) | — | IP30 |
| IP rating (rear) | — | IP30 |
| Operating temperature | -20 to 40 °C | -10 to 45 °C |
| Service access | Front | Front |
| LED lifetime | 100,000 h | 100,000 h |
| Certifications | CE, FCC, cTUVus, CB, KC, CCC, EMC Class A, EN 13501-1 | — |
Size a wall with either panel
The calculator shows dimensions, power, weight and a validated wiring diagram for both — swap cabinets with one click.